Development of calibration system for transmission control unit of AT based on XCP

Gang Tao*, De Qing Li, Yue Feng Ma, Li Juan Duan

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

1 引用 (Scopus)

摘要

To guarantee control system's performance and shorten the development cycle during the development process of hydraulic automatic transmission, a calibration system on CAN for high-power AT ECU is designed based on XCP. In this system, it is possible that the master dynamically searching the slaves available on bus and data synchronization between master and slave is also achieved. Real-time measurement and on-line calibration can be executed during the running process of transmission control unit, so the calibration result is displayed in time. Calibration by true value and physical value are both available. Experimental results showed that this system operated stably and reliably and had strong timeout handling ability.

源语言英语
页(从-至)28-34
页数7
期刊Journal of Beijing Institute of Technology (English Edition)
22
1
出版状态已出版 - 3月 2013

指纹

探究 'Development of calibration system for transmission control unit of AT based on XCP' 的科研主题。它们共同构成独一无二的指纹。

引用此