Virtual stenting with simplex mesh and mechanical contact analysis for real-time planning of thoracic endovascular aortic repair

Duanduan Chen*, Jianyong Wei, Yiming Deng, Huanming Xu, Zhenfeng Li, Haoye Meng, Xiaofeng Han, Yonghao Wang, Jia Wan, Tianyi Yan, Jiang Xiong, Xiaoying Tang

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

28 引用 (Scopus)

摘要

In aortic endovascular repair, the prediction of stented vessel remodeling informs treatment plans and risk evaluation; however, there are no highly accurate and efficient methods to quantitatively simulate stented vessels. This study developed a fast virtual stenting algorithm to simulate stent-induced aortic remodeling to assist in real-time thoracic endovascular aortic repair planning. Methods: The virtual stenting algorithm was established based on simplex deformable mesh and mechanical contact analysis. The key parameters of the mechanical contact analysis were derived from mechanical tests on aortic tissue (n=40) and commonly used stent-grafts (n=6). Genetic algorithm was applied to select weighting parameters. Testing and validation of the algorithm were performed using pre- and post-treatment computed tomography angiography datasets of type-B aortic dissection cases (n=66). Results: The algorithm was efficient in simulating stent-induced aortic deformation (mean computing time on a single processor: 13.78±2.80s) and accurate at the morphological (curvature difference: 1.57±0.57%; cross-sectional area difference: 4.11±0.85%) and hemodynamic (similarity of wall shear stress-derived parameters: 90.16-90.94%) levels. Stent-induced wall deformation was higher (p<0.05) in distal stent-induced new entry cases than in successfully treated cases, and this deformation did not differ significantly among the different stent groups. Additionally, the high stent-induced wall deformation regions and the new-entry sites overlapped, indicating the usefulness of wall deformation to evaluate the risks of device-induced complications. Conclusion: The novel algorithm provided fast real-time and accurate predictions of stent-graft deployment with luminal deformation tracking, thereby potentially informing individualized stenting planning and improving endovascular aortic repair outcomes. Large, multicenter studies are warranted to extend the algorithm validation and determine stress-induced wall deformation cutoff values for the risk stratification of particular complications.

源语言英语
页(从-至)5758-5771
页数14
期刊Theranostics
8
20
DOI
出版状态已出版 - 2018

指纹

探究 'Virtual stenting with simplex mesh and mechanical contact analysis for real-time planning of thoracic endovascular aortic repair' 的科研主题。它们共同构成独一无二的指纹。

引用此