TY - JOUR
T1 - The design of abnormal microenvironment responsive mri nanoprobe and its application
AU - Wang, Ancong
AU - Han, Xiao
AU - Qi, Wenliu
AU - Du, Sihui
AU - Jiang, Zhenqi
AU - Tang, Xiaoying
N1 - Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2021/5/2
Y1 - 2021/5/2
N2 - Magnetic resonance imaging (MRI) is often used to diagnose diseases due to its high spatial, temporal and soft tissue resolution. Frequently, probes or contrast agents are used to enhance the contrast in MRI to improve diagnostic accuracy. With the development of molecular imaging techniques, molecular MRI can be used to obtain 3D anatomical structure, physiology, pathology, and other relevant information regarding the lesion, which can provide an important reference for the accurate diagnosis and treatment of the disease in the early stages. Among existing contrast agents, smart or activatable nanoprobes can respond to selective stimuli, such as proving the presence of acidic pH, active enzymes, or reducing environments. The recently developed environment-responsive or smart MRI nanoprobes can specifically target cells based on differences in the cellular environment and improve the contrast between diseased tissues and normal tissues. Here, we review the design and application of these environment-responsive MRI nanoprobes.
AB - Magnetic resonance imaging (MRI) is often used to diagnose diseases due to its high spatial, temporal and soft tissue resolution. Frequently, probes or contrast agents are used to enhance the contrast in MRI to improve diagnostic accuracy. With the development of molecular imaging techniques, molecular MRI can be used to obtain 3D anatomical structure, physiology, pathology, and other relevant information regarding the lesion, which can provide an important reference for the accurate diagnosis and treatment of the disease in the early stages. Among existing contrast agents, smart or activatable nanoprobes can respond to selective stimuli, such as proving the presence of acidic pH, active enzymes, or reducing environments. The recently developed environment-responsive or smart MRI nanoprobes can specifically target cells based on differences in the cellular environment and improve the contrast between diseased tissues and normal tissues. Here, we review the design and application of these environment-responsive MRI nanoprobes.
KW - Application
KW - Design
KW - Environment responsive
KW - MRI nanoprobe
UR - http://www.scopus.com/inward/record.url?scp=85105747154&partnerID=8YFLogxK
U2 - 10.3390/ijms22105147
DO - 10.3390/ijms22105147
M3 - Article
C2 - 34067989
AN - SCOPUS:85105747154
SN - 1661-6596
VL - 22
JO - International Journal of Molecular Sciences
JF - International Journal of Molecular Sciences
IS - 10
M1 - 5147
ER -