T1 - Research on fault location based on PMU for multi-source distribution network
AU - Mengsheng, Zhang
AU - Yi, Wang
AU - Zhou, Zhiguo
AU - Li, Zufu
N1 - Publisher Copyright:
© 2016 IEEE.
PY - 2016/12/9
Y1 - 2016/12/9
N2 - Accurate fault location is beneficial for the stability of power distribution network. With the access of distributed energy resource, such as distributed generations, electric vehicles, controllable load and so on, traditional fault and protection device has been unable to completely adopt to the new situation of distribution network protection, which requires new technologies and devices. In this paper, a new method based on phasor measurement unit, termed PMU or synchrophasor, is proposed to locate the fault in the multi-source distribution network. The location method uses the voltage and current information of PMU on one terminal to iterating every line segment, the candidate faults and its fault distance are calculated. By means of voltage phase relationship between fault voltage and measured voltage of PMUs on two terminals to get the actual fault location and eliminate the pseudo fault locations, with the characteristic of high-precision and clock synchronization in PMU. Finally, the simulation results show that the location method has high position accuracy in the multi-source distribution network by the algorithm simulation analysis based on Matlab/Simulink platform. The method can satisfy different types of fault with simply installing PMUs only on the two terminals of the circuit. And still has high location accuracy with the influence of high DG penetration and high resistance faults.
AB - Accurate fault location is beneficial for the stability of power distribution network. With the access of distributed energy resource, such as distributed generations, electric vehicles, controllable load and so on, traditional fault and protection device has been unable to completely adopt to the new situation of distribution network protection, which requires new technologies and devices. In this paper, a new method based on phasor measurement unit, termed PMU or synchrophasor, is proposed to locate the fault in the multi-source distribution network. The location method uses the voltage and current information of PMU on one terminal to iterating every line segment, the candidate faults and its fault distance are calculated. By means of voltage phase relationship between fault voltage and measured voltage of PMUs on two terminals to get the actual fault location and eliminate the pseudo fault locations, with the characteristic of high-precision and clock synchronization in PMU. Finally, the simulation results show that the location method has high position accuracy in the multi-source distribution network by the algorithm simulation analysis based on Matlab/Simulink platform. The method can satisfy different types of fault with simply installing PMUs only on the two terminals of the circuit. And still has high location accuracy with the influence of high DG penetration and high resistance faults.
KW - PMU
KW - distributed generation
KW - fault location
KW - high impedance fault
KW - multi-source distribution network
UR - http://www.scopus.com/inward/record.url?scp=85009986795&partnerID=8YFLogxK
U2 - 10.1109/APPEEC.2016.7779815
DO - 10.1109/APPEEC.2016.7779815
M3 - Conference contribution
AN - SCOPUS:85009986795
T3 - Asia-Pacific Power and Energy Engineering Conference, APPEEC
SP - 1877
EP - 1882
BT - IEEE PES APPEEC 2016 - 2016 IEEE PES Asia Pacific Power and Energy Engineering Conference
PB - IEEE Computer Society
T2 - 2016 IEEE PES Asia Pacific Power and Energy Engineering Conference, APPEEC 2016
Y2 - 25 October 2016 through 28 October 2016
ER -