Novel method for maximum range measure of pulse laser range finder

Chang E. Zeng*, Qian Qian Wang, Gang Chang, Chang Sheng Shan, Qiang Wang

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

10 引用 (Scopus)

摘要

Maximum range is one of the major parameters of pulse laser range finder. Several common measurement methods are analyzed. A novel method combining outdoor light extinction ratio with indoor time sequence gain coefficient ratio is proposed. For two pulse laser range finders, outdoor light extinction ratio, indoor time sequence coefficient and maximum range are measured and compared. The results and error analysis are given. The results prove that the maximum range of the pulse laser range finder whose operating wavelength is 1.06 μm and 1.54 μm could be measured accurately, and it is hardly effected by weather condition and target properties, nor is effected by time sequence gain circuit. The method has high accuracy, repeatability and serviceability. By this method, other major parameters of the pulse laser range finder such as ranging accuracy, gating range, gating accuracy and range resolution can also be measured.

源语言英语
页(从-至)664-668+672
期刊Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering
34
6
出版状态已出版 - 12月 2005

指纹

探究 'Novel method for maximum range measure of pulse laser range finder' 的科研主题。它们共同构成独一无二的指纹。

引用此