摘要
Combining structural dynamics with the control theory of a shaking table, the dynamic model of a 4m×6m self-assembled shaking table was derived. Its oil column resonances and damping parameters were then obtained based on simulations. At the same time, a detailed test analysis was given according to actual model tests. Theoretical and experimental results showed that a 3-parameter control model was more effective to improve the dynamic characteristics of the system to meet additional test requirements.
源语言 | 英语 |
---|---|
页(从-至) | 99-102+106 |
期刊 | Zhendong yu Chongji/Journal of Vibration and Shock |
卷 | 29 |
期 | 2 |
出版状态 | 已出版 - 2月 2010 |
已对外发布 | 是 |