TY - JOUR
T1 - A non-enzymatic urine glucose sensor with 2-D photonic crystal hydrogel
AU - Yan, Zequn
AU - Xue, Min
AU - He, Qian
AU - Lu, Wei
AU - Meng, Zihui
AU - Yan, Dan
AU - Qiu, Lili
AU - Zhou, Lijun
AU - Yu, Yingjie
N1 - Publisher Copyright:
© 2016, Springer-Verlag Berlin Heidelberg.
PY - 2016/11/1
Y1 - 2016/11/1
N2 - A novel polymerized crystalline colloidal array (PCCA) sensing material for the detection of urine glucose was developed by embedding a two-dimensional (2-D) polystyrene crystalline colloidal array (CCA) in 3-acrylamidophenylboronic acid (3-APBA)-functionalized hydrogel. After adjusting the cross-linker concentration, this material showed significant sensitivity for glucose under lab conditions, the particle spacing of the PCCA changed from 917 to 824 nm (93 nm) within 3 min as the glucose concentration increased from 0 to 10 mM, and the structural color of the PCCA changed from red through orange, to green, and finally, to cyan. In further experiments, this material was used to semi-quantitatively detect glucose in 20 human urine (HU) samples. Compared with the traditional dry-chemistry method, which was applied widely in clinical diagnosis, the PCCA method was more accurate and cost-effective. Moreover, this method can efficiently avoid the errors induced by most of the urine-interfering elements like vitamin C and ketone body. With a homemade portable optical detector, this low-cost intelligent sensing material can provide a more convenient and efficient strategy for the urine glucose detection in clinical diagnosis and point-of-care monitoring.
AB - A novel polymerized crystalline colloidal array (PCCA) sensing material for the detection of urine glucose was developed by embedding a two-dimensional (2-D) polystyrene crystalline colloidal array (CCA) in 3-acrylamidophenylboronic acid (3-APBA)-functionalized hydrogel. After adjusting the cross-linker concentration, this material showed significant sensitivity for glucose under lab conditions, the particle spacing of the PCCA changed from 917 to 824 nm (93 nm) within 3 min as the glucose concentration increased from 0 to 10 mM, and the structural color of the PCCA changed from red through orange, to green, and finally, to cyan. In further experiments, this material was used to semi-quantitatively detect glucose in 20 human urine (HU) samples. Compared with the traditional dry-chemistry method, which was applied widely in clinical diagnosis, the PCCA method was more accurate and cost-effective. Moreover, this method can efficiently avoid the errors induced by most of the urine-interfering elements like vitamin C and ketone body. With a homemade portable optical detector, this low-cost intelligent sensing material can provide a more convenient and efficient strategy for the urine glucose detection in clinical diagnosis and point-of-care monitoring.
KW - Photonic crystal
KW - Point-of-care monitoring
KW - Urine glucose
KW - Visual detection
UR - http://www.scopus.com/inward/record.url?scp=84988970302&partnerID=8YFLogxK
U2 - 10.1007/s00216-016-9947-4
DO - 10.1007/s00216-016-9947-4
M3 - Article
C2 - 27682838
AN - SCOPUS:84988970302
SN - 1618-2642
VL - 408
SP - 8317
EP - 8323
JO - Analytical and Bioanalytical Chemistry
JF - Analytical and Bioanalytical Chemistry
IS - 29
ER -