Abstract

In monostatic ISAR imaging, the radar cannot be imaged when there is no obvious change of viewing angle relative to the target. Nevertheless, the bistatic (multi-base) radar system can realize imaging by observing targets from multiple perspectives. In this paper, a bistatic ISAR imaging method is adopted, and its imaging principle is analyzed in detail. Then its signal processing model and signal processing flow are introduced. This method eliminates the migration through resolution cell (MTRC). Finally, this algorithm is verified by the scaled model experiment in the anechoic chamber.

Original languageEnglish
Title of host publicationIET Conference Proceedings
PublisherInstitution of Engineering and Technology
Pages1666-1672
Number of pages7
Volume2020
Edition9
ISBN (Electronic)9781839535406
DOIs
Publication statusPublished - 2020
Event5th IET International Radar Conference, IET IRC 2020 - Virtual, Online
Duration: 4 Nov 20206 Nov 2020

Conference

Conference5th IET International Radar Conference, IET IRC 2020
CityVirtual, Online
Period4/11/206/11/20

Keywords

  • Keystone transformation
  • MTRC
  • bistatic ISAR system
  • scaled model experiments

Fingerprint

Dive into the research topics of 'Scaled model experiments for bistatic ISAR system'. Together they form a unique fingerprint.