Abstract
Micromechanical behaviors of Zr-based metallic glass/porous tungsten composite under quasi-static uniaxial compression at room temperature were investigated by in-situ high-energy X-ray diffraction (HEXRD) technique based on the synchrotron source and finite element modeling (FEM). During the process of compression, the main load phase was tungsten phase until it yielded at an applied stress of 1175. MPa. Subsequently, metallic glass phase became the main load phase. The plastic misfit strain of the two phases resulted in stress concentration near interfaces between them, which accelerated the process of stress transfer from the tungsten phase to the metallic glass phase. The metallic glass phase started to yield at 1500. MPa; at that time defects weakened the mutual restriction between the metallic glass phase and the tungsten phase, leading the tungsten phase to fail or the interfaces between two phases to separate by the increasing load.
Original language | English |
---|---|
Pages (from-to) | 407-412 |
Number of pages | 6 |
Journal | Materials Science and Engineering: A |
Volume | 598 |
DOIs | |
Publication status | Published - 26 Mar 2014 |
Keywords
- Composite
- Finite element analysis (FEA)
- High energy X-ray diffraction (HEXRD)
- Mechanical properties
- Metallic glass