Ion detection of 2, 4-dinitroanisole by ion chromatography

Si Yu Wu, Qiao Zhu, Min Xue, Zhi Qun Chen, Min Xu, Lin Jia, Min Chang Wang, Zhi Hui Lin, Zi Hui Meng*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

To determine the trace ions in energetic compound 2, 4-dinitroanisole (DNAN) sample, the qualitative and quantitative analysis of ions in DNAN sample were performed by an ion chromatography method. Results show that the sample contains 8 kinds of ions of Li+, Na+, NH4+, Mg2+, Ca2+, Cl-, NO3-, SO42-. Their mass fractions are 13.2348, 70.4080, 15.3270, 83.2659, 154.1580, 156.4740, 21.6544, 210.3100μg/mL, respectively. The method has the advantages of rapid detection and reliable quantification.