An interferometric imaging biosensor using weighted spectrum analysis to confirm DNA monolayer films with attogram sensitivity

Rongxin Fu, Qi Li, Ruliang Wang, Ning Xue, Xue Lin, Ya Su, Kai Jiang, Xiangyu Jin, Rongzan Lin, Wupeng Gan, Ying Lu, Guoliang Huang*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

11 Citations (Scopus)

Abstract

Interferometric imaging biosensors are powerful and convenient tools for confirming the existence of DNA monolayer films on silicon microarray platforms. However, their accuracy and sensitivity need further improvement because DNA molecules contribute to an inconspicuous interferometric signal both in thickness and size. Such weaknesses result in poor performance of these biosensors for low DNA content analyses and point mutation tests. In this paper, an interferometric imaging biosensor with weighted spectrum analysis is presented to confirm DNA monolayer films. The interferometric signal of DNA molecules can be extracted and then quantitative detection results for DNA microarrays can be reconstructed. With the proposed strategy, the relative error of thickness detection was reduced from 88.94% to merely 4.15%. The mass sensitivity per unit area of the proposed biosensor reached 20 attograms (ag). Therefore, the sample consumption per unit area of the target DNA content was only 62.5 zeptomoles (zm), with the volume of 0.25 picolitres (pL). Compared with the fluorescence resonance energy transfer (FRET), the measurement veracity of the interferometric imaging biosensor with weighted spectrum analysis is free to the changes in spotting concentration and DNA length. The detection range was more than 1 µm. Moreover, single nucleotide mismatch could be pointed out combined with specific DNA ligation. A mutation experiment for lung cancer detection proved the high selectivity and accurate analysis capability of the presented biosensor.

Original languageEnglish
Pages (from-to)224-231
Number of pages8
JournalTalanta
Volume181
DOIs
Publication statusPublished - 1 May 2018
Externally publishedYes

Keywords

  • Attogram sensitivity
  • Interferometric biosensor
  • Point mutation detection
  • Sub-nanoscale accuracy

Fingerprint

Dive into the research topics of 'An interferometric imaging biosensor using weighted spectrum analysis to confirm DNA monolayer films with attogram sensitivity'. Together they form a unique fingerprint.

Cite this

Fu, R., Li, Q., Wang, R., Xue, N., Lin, X., Su, Y., Jiang, K., Jin, X., Lin, R., Gan, W., Lu, Y., & Huang, G. (2018). An interferometric imaging biosensor using weighted spectrum analysis to confirm DNA monolayer films with attogram sensitivity. Talanta, 181, 224-231. https://doi.org/10.1016/j.talanta.2017.12.066