摘要
The influence factors and process of indoor gas explosion are studied with AutoReaGas explosion simulator. The result shows that venting pressure has great influence on the indoor gas explosion damage. The higher the venting pressure is, the more serious the hazard consequence will be. The ignition location has also evident effect on the gas explosion damage. The explosion static overpressure would not cause major injury to person and serious damage to structure in the case of low venting pressure (lower than 2 kPa). The high temperature combustion after the explosion is the major factor to person injury in indoor gas explosion accidents.
源语言 | 英语 |
---|---|
页(从-至) | 286-289 |
页数 | 4 |
期刊 | Journal of Beijing Institute of Technology (English Edition) |
卷 | 12 |
期 | 3 |
出版状态 | 已出版 - 9月 2003 |
指纹
探究 'Simulation analysis of indoor gas explosion damage' 的科研主题。它们共同构成独一无二的指纹。引用此
Qian, X. M., Chen, L. S., & Feng, C. G. (2003). Simulation analysis of indoor gas explosion damage. Journal of Beijing Institute of Technology (English Edition), 12(3), 286-289.