Optimum optical length of the gas cell used for monitoring gas-in-oil with FTIR

Xian Yong Liu*, Feng Lei Huang, Xia Wang, Fang Jie Zhou

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

2 引用 (Scopus)

摘要

Dedicated experiments are designed to collect the infrared spectra of dissolved gas-in-oil of power transformers. Spectra of diagnostic gases are collected by 3 different laboratorial FTIR spectrometers using 3 different gas cells with various sets of equipment parameters. A formula is deduced to calculate the shortest optical length to detect a specific concentration according to measurements on gases with known concentrations near to the minimum detection limit. Collected spectra and calculated results suggested that the optimum optical length of the gas cell should be 150 mm to realize on-line monitoring of diagnostic gases within the required concentration range. At the end, an economic novel design of the gas cell is proposed based on the optimum length.

源语言英语
页(从-至)59-63
页数5
期刊Journal of Beijing Institute of Technology (English Edition)
12
1
出版状态已出版 - 3月 2003

指纹

探究 'Optimum optical length of the gas cell used for monitoring gas-in-oil with FTIR' 的科研主题。它们共同构成独一无二的指纹。

引用此

Liu, X. Y., Huang, F. L., Wang, X., & Zhou, F. J. (2003). Optimum optical length of the gas cell used for monitoring gas-in-oil with FTIR. Journal of Beijing Institute of Technology (English Edition), 12(1), 59-63.