Incorporation of axiomatic design theory into design of a microchannel system for uniform and size-controllable microspheres

Ki Young Song, W. J. Zhang*, Madan M. Gupta

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

7 引用 (Scopus)

摘要

This paper proposes a design methodology for the conceptual design of microchannel systems by applying axiomatic design theory (ADT). The microchannel system concerned in this paper is for the purpose of preparing uniform microspheres based on the phase separation principle and technique. There are two general design goals for this system: controllability of the size of microspheres and uniformity, or narrow size distribution, of microspheres. The conventional microchannel system designs in literature are found poor according to a particular ADT design characteristic called "coupled design." This paper proposes a "decoupled design" process which is considered better than a "coupled design" process according to ADT. The paper demonstrates the effectiveness of such a "decoupled design" process with a new microchannel system, based on the simulation of the two performance goals.

源语言英语
页(从-至)491-499
页数9
期刊International Journal of Advanced Manufacturing Technology
57
5-8
DOI
出版状态已出版 - 11月 2011
已对外发布

指纹

探究 'Incorporation of axiomatic design theory into design of a microchannel system for uniform and size-controllable microspheres' 的科研主题。它们共同构成独一无二的指纹。

引用此