TY - JOUR
T1 - Extensible automated dispersive liquid-liquid microextraction
AU - Li, Songqing
AU - Hu, Lu
AU - Chen, Ketao
AU - Gao, Haixiang
N1 - Publisher Copyright:
© 2015 Elsevier B.V.
PY - 2015/5/4
Y1 - 2015/5/4
N2 - In this study, a convenient and extensible automated ionic liquid-based in situ dispersive liquid-liquid microextraction (automated IL-based in situ DLLME) was developed. 1-Octyl-3-methylimidazolium bis[(trifluoromethane)sulfonyl]imide ([C8MIM]NTf2) is formed through the reaction between [C8MIM]Cl and lithium bis[(trifluoromethane)sulfonyl]imide (LiNTf2) to extract the analytes. Using a fully automatic SPE workstation, special SPE columns packed with nonwoven polypropylene (NWPP) fiber, and a modified operation program, the procedures of the IL-based in situ DLLME, including the collection of a water sample, injection of an ion exchange solvent, phase separation of the emulsified solution, elution of the retained extraction phase, and collection of the eluent into vials, can be performed automatically. The developed approach, coupled with high-performance liquid chromatography-diode array detection (HPLC-DAD), was successfully applied to the detection and concentration determination of benzoylurea (BU) insecticides in water samples. Parameters affecting the extraction performance were investigated and optimized. Under the optimized conditions, the proposed method achieved extraction recoveries of 80% to 89% for water samples. The limits of detection (LODs) of the method were in the range of 0.16-0.45ngmL-1. The intra-column and inter-column relative standard deviations (RSDs) were <8.6%. Good linearity (r>0.9986) was obtained over the calibration range from 2 to 500ngmL-1. The proposed method opens a new avenue for automated DLLME that not only greatly expands the range of viable extractants, especially functional ILs but also enhances its application for various detection methods. Furthermore, multiple samples can be processed simultaneously, which accelerates the sample preparation and allows the examination of a large number of samples.
AB - In this study, a convenient and extensible automated ionic liquid-based in situ dispersive liquid-liquid microextraction (automated IL-based in situ DLLME) was developed. 1-Octyl-3-methylimidazolium bis[(trifluoromethane)sulfonyl]imide ([C8MIM]NTf2) is formed through the reaction between [C8MIM]Cl and lithium bis[(trifluoromethane)sulfonyl]imide (LiNTf2) to extract the analytes. Using a fully automatic SPE workstation, special SPE columns packed with nonwoven polypropylene (NWPP) fiber, and a modified operation program, the procedures of the IL-based in situ DLLME, including the collection of a water sample, injection of an ion exchange solvent, phase separation of the emulsified solution, elution of the retained extraction phase, and collection of the eluent into vials, can be performed automatically. The developed approach, coupled with high-performance liquid chromatography-diode array detection (HPLC-DAD), was successfully applied to the detection and concentration determination of benzoylurea (BU) insecticides in water samples. Parameters affecting the extraction performance were investigated and optimized. Under the optimized conditions, the proposed method achieved extraction recoveries of 80% to 89% for water samples. The limits of detection (LODs) of the method were in the range of 0.16-0.45ngmL-1. The intra-column and inter-column relative standard deviations (RSDs) were <8.6%. Good linearity (r>0.9986) was obtained over the calibration range from 2 to 500ngmL-1. The proposed method opens a new avenue for automated DLLME that not only greatly expands the range of viable extractants, especially functional ILs but also enhances its application for various detection methods. Furthermore, multiple samples can be processed simultaneously, which accelerates the sample preparation and allows the examination of a large number of samples.
KW - Automated dispersive liquid-liquid microextraction
KW - Benzoylurea insecticides
KW - Fully automatic SPE workstation
KW - Ionic liquid
KW - Nonwoven polypropylene fiber
UR - http://www.scopus.com/inward/record.url?scp=84928208979&partnerID=8YFLogxK
U2 - 10.1016/j.aca.2015.02.061
DO - 10.1016/j.aca.2015.02.061
M3 - Article
AN - SCOPUS:84928208979
SN - 0003-2670
VL - 872
SP - 46
EP - 54
JO - Analytica Chimica Acta
JF - Analytica Chimica Acta
ER -