Error analysis of a stereo-vision-based tube measurement system

Hao Huang, Jianhua Liu, Shaoli Liu*, Peng Jin, Tianyi Wu, Tian Zhang

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

14 引用 (Scopus)

摘要

To ensure the accuracy of tube measurement systems based on multi-stereo vision, we defined error sources and their modes of transmission through the system, and developed an error propagation model. In this paper, we first discuss system processes including camera calibration, image processing, point-to-point matching, three-dimensional reconstruction, and error sources identification. Next, we develop a theoretical error calculation equation based on our proposed error propagation model. Experimental verification results showed a practical measurement error of 0.17 mm; the error associated with our proposed theoretical error calculations was 0.192 mm, verifying the utility of the model. The proposed model is expected to help researchers rapidly establish accurate measurement systems that are capable of accommodating processing challenges.

源语言英语
文章编号107659
期刊Measurement: Journal of the International Measurement Confederation
157
DOI
出版状态已出版 - 6月 2020

指纹

探究 'Error analysis of a stereo-vision-based tube measurement system' 的科研主题。它们共同构成独一无二的指纹。

引用此