Chemically induced alteration in PAC characteristics and its influences on PAC/UF water treatment: Implications for on-line membrane cleaning with NaClO

Zeyuan Gao, Zhi Ping Zhao, Weiwei Cai*

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

10 引用 (Scopus)

摘要

The integrated PAC/UF technique has gained increasing applications in water treatment systems. However, the fouling and substantial PAC deposition on membrane surfaces remain perennial hurdles. To tackle these issues, on-line membrane cleaning with NaClO should be frequently performed to sustain the membrane permeability, leading to the inevitable contact between NaClO and PAC particles, which may significantly change the PAC properties, hence the entire performance of water treatment during the next round of operation. This study simulated the two reactions between PACs and NaClO (i.e. deposited PAC with high-concentration NaClO and suspended PAC with low-concentration NaClO) based on the current practice of on-line membrane cleaning, and further investigated the impacts of NaClO-induced PAC variations on PAC/UF performance. The results showed that (i) the adsorption capacities of altered PACs for humic acid (HA), bovine serum albumin (BSA) as well as contaminants in surface water were seriously weakened because of the decreased specific surface area and pore volume; (ii) The altered PAC surface became more hydrophilic, presumably leading to the higher deposition on membrane surface. Besides, (iii) the PAC deposition amounts were all enhanced by the presence of BSA, while substantially decreased by HA. Further addition of Ca2+ with HA dramatically increased PAC deposition probably by forming the cross-linked molecular chains to connect PAC-PAC or PAC-membrane. As a result, membrane fouling in PAC/UF water treatment system was remarkedly aggravated when the altered PACs were applied due to NaClO exposure. Meanwhile, the surface water treatment performances in terms of CODMn removal, UV254 removal and turbidity removal significantly decreased, implying the adverse impacts of employing such altered PAC in the practical water treatment system. Given on-line chemical cleaning is frequently conducted during a long-term operation, the current study raised serious concerns on membrane cleaning induced PAC variations and potentially negative influences on the real-life PAC/UF water treatment process.

源语言英语
文章编号121130
期刊Separation and Purification Technology
294
DOI
出版状态已出版 - 1 8月 2022

指纹

探究 'Chemically induced alteration in PAC characteristics and its influences on PAC/UF water treatment: Implications for on-line membrane cleaning with NaClO' 的科研主题。它们共同构成独一无二的指纹。

引用此