TY - JOUR
T1 - Bioresorbable Pressure Sensor and Its Applications in Abnormal Respiratory Event Identification
AU - Li, Zhe
AU - Li, Cong
AU - Deng, Yulin
N1 - Publisher Copyright:
© 2023 American Chemical Society.
PY - 2023/3/28
Y1 - 2023/3/28
N2 - Bioresorbable electronics that can be absorbed and become a part of the organism after their service life are becoming a trend to avoid secondary invasive surgery. However, the sustainable and secure supply of energy for biosensors is a significant challenge. Here, a bioresorbable pressure sensor (BPS) based on a triboelectric nanogenerator is reported. The BPS based on the triboelectric nanogenerator can directly convert ambient pressure changes into electrical signals. It offers excellent sensitivity (22.61 mV/mmHg), linearity (R2 = 0.99), and good durability (850,000 cycles). The bioresorbable materials of poly(lactic acid)/chitosan/sodium alginate in the BPS show great biocompatibility and can achieve 99.99% sterilization for both Gram-positive bacteria and Gram-negative bacteria. In addition, the device can successfully identify an abnormal respiratory event in small animals and will be completely degraded after 21 days. The BPS only employs medical materials used commonly in FDA-approved implants, which is crucial for the biosafety of bioresorbable devices. Triboelectric devices are expected to be applied in the clinic as bioresorbable electronics.
AB - Bioresorbable electronics that can be absorbed and become a part of the organism after their service life are becoming a trend to avoid secondary invasive surgery. However, the sustainable and secure supply of energy for biosensors is a significant challenge. Here, a bioresorbable pressure sensor (BPS) based on a triboelectric nanogenerator is reported. The BPS based on the triboelectric nanogenerator can directly convert ambient pressure changes into electrical signals. It offers excellent sensitivity (22.61 mV/mmHg), linearity (R2 = 0.99), and good durability (850,000 cycles). The bioresorbable materials of poly(lactic acid)/chitosan/sodium alginate in the BPS show great biocompatibility and can achieve 99.99% sterilization for both Gram-positive bacteria and Gram-negative bacteria. In addition, the device can successfully identify an abnormal respiratory event in small animals and will be completely degraded after 21 days. The BPS only employs medical materials used commonly in FDA-approved implants, which is crucial for the biosafety of bioresorbable devices. Triboelectric devices are expected to be applied in the clinic as bioresorbable electronics.
KW - biodegradable
KW - electronics
KW - pressure sensor
KW - respiratory identification
KW - triboelectric nanogenerator
UR - http://www.scopus.com/inward/record.url?scp=85148948558&partnerID=8YFLogxK
U2 - 10.1021/acsaelm.2c01782
DO - 10.1021/acsaelm.2c01782
M3 - Article
AN - SCOPUS:85148948558
SN - 2637-6113
VL - 5
SP - 1761
EP - 1769
JO - ACS Applied Electronic Materials
JF - ACS Applied Electronic Materials
IS - 3
ER -