An Integrated Biological Analysis and Flow Rate Sensing for the Real-Time Detection of Carcinogen in Water Based on Co2+-Doped Optical Fibers

Ran Gao*, Jiansen Ye, Xiangjun Xin

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

7 引用 (Scopus)

摘要

The multi-parameter measurement has significant meaning for biosensor to enhance their practical sensing performance. For the biological detection, simultaneous measurement of biological molecule and flow rate could improve the accuracy and sensitivity of sensors significantly. In this paper, an integrated biological analysis and flow rate sensing based on Co2+ doped tilted fiber Bragg gratings has been proposed and experimentally demonstrated for real-time the detection of the Benzo[a]pyrene molecules. A tilted fiber Bragg grating with a tilted angle of 8° was inscribed into a Co2+ doped fiber. The flow rate and Benzo[a]pyrene molecules can be measured simultaneously by interrogating the resonance wavelength of core mode and wavelength interval between the core mode and cladding mode according to the heat exchange and evanescent field of the cladding mode, respectively. Experimental results show that the real-time measurement sensitivities of 12 pm/pM and -0.13 nm/( $\mu \text{L}$ /s) for the Benzo[a]pyrene detection and flow rate were achieved, respectively. Thus the technique appears to have potential applications in chemistry, medicine, and biology.

源语言英语
文章编号8879587
页(从-至)1912-1921
页数10
期刊IEEE Sensors Journal
20
4
DOI
出版状态已出版 - 15 2月 2020

指纹

探究 'An Integrated Biological Analysis and Flow Rate Sensing for the Real-Time Detection of Carcinogen in Water Based on Co2+-Doped Optical Fibers' 的科研主题。它们共同构成独一无二的指纹。

引用此