摘要
A decoupling operation model has been developed for the helical magnetic flux compression generator. The model reveals the mechanism of losses with analytical expressions and clearly physical implication. Based on the proposed model, the experiment and simulation were implemented for the compact cascading magnetic flux compression generator with more complex losses mechanism. The results show that experimental results are in compliance well with the simulation results of the model. The current waveforms of experiment and simulation vary in the same trend, in which the change of transition is clear at the pitch points of stator. At the smooth segment of stator, the consistency of experimental waveforms with simulation ones is even better.
源语言 | 英语 |
---|---|
页(从-至) | 673-676 |
页数 | 4 |
期刊 | Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology |
卷 | 32 |
期 | 7 |
出版状态 | 已出版 - 7月 2012 |