市售牛奶快速 ATR-FTIR 主成分分析

Yu Feng, Yun Hong Zhang*

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

摘要

The determination of the main components of milk is an important criterion for evaluating the quality of milk. Relevant national departments have formulated a series of relatively detailed specifications to ensure the quality and safety of milk and other dairy products. However, the traditional detection methods are often complex, time-consuming and labor-intensive. Some even cause environmental pollution, making it difficult to meet the rapid detection needs of contemporary dairy production and consumption. In this study, the portable attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) technique was combined with relative humidity (RH) control system to establish a method to measure the infrared spectra of different kinds of milk under the condition of continuous decline of RH. This method provides a new way for non-destructive testing, classification and quality analysis of milk products. The main contents include:(1)Selecting five types of milk of YiLi brand (pure milk, Zhennong milk, skimmed pure milk, high-calcium low-fat milk, and Shuhua milk) as research objects. Whose infrared spectra in the process of evaporation and concentration were collected under continuous decline of RH, and the peak position attribution and qualitative analysis of main nutritional components were carried out. It only takes a few microliters of milk samples for us to obtain the spectral information of the main components, such as water, carbohydrates, fats, and proteins, during the sample concentration process in a short time and achievea relatively comprehensive characterization of the chemical components of milk; (2) Using NWUSA software to build the model and process the infrared spectral data, choosing 4 000~400 cm-1 band as the variables to perform PCA and evaluating the identification ability of the model for different types of milk, it shows that the data of PCA process are well aggregated in the same group. The coordinate axes in different groups are far apart, indicating that the model selection is both reliable and representative. A total of 75 milk samples were used in the experiment, in which the production date and place were random factors, and the type and brand of milk were fixed factors. The results show that the proposed method has the advantages of simple operation, sensitive response, high spectral quality and nondestructive measurement, which is suitable for in-situ, rapid and non-destructive identification and analysis of milk and other dairy products.

投稿的翻译标题Rapid ATR-FTIR Principal Component Analysis of Commercial Milk
源语言繁体中文
页(从-至)838-841
页数4
期刊Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis
43
3
DOI
出版状态已出版 - 3月 2023

关键词

  • ATR-FTIR
  • Continuous decline of RH
  • Milk
  • PCA

指纹

探究 '市售牛奶快速 ATR-FTIR 主成分分析' 的科研主题。它们共同构成独一无二的指纹。

引用此