Study of the accuracy of transit time ultrasonic flow measurement for liquids

Liling Ma*, Kun Guo, Junzheng Wang

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

14 Citations (Scopus)

Abstract

High-precision measurement of liquid flow using transit time method requires accurate measurements of the absolute propagation time and the relative propagation time. The reference signal for the measurement of the absolute propagation time in ultrasonic flow measurement is rather difficult to get. Aiming at this problem, an extraction method of the reference signal is presented. The boundary conditions for energy and phase are set to ensure the accuracy of the extracted reference signal, which can adaptively adjust the fundamental signals according to the actual velocity distribution interval. The sampling rate and peak detector factors that influence the precision of the relative time difference are further studied with simulation analysis; An experimental system is designed and the proposed method and the simulation analysis are verified on a hydraulic platform. The results prove the effectiveness of the method and the correctness of the simulation analysis.

Original languageEnglish
Pages (from-to)1028-1034
Number of pages7
JournalYi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument
Volume33
Issue number5
Publication statusPublished - May 2012

Keywords

  • Peak detection
  • Propagation time
  • Reference signal
  • Sampling rate

Fingerprint

Dive into the research topics of 'Study of the accuracy of transit time ultrasonic flow measurement for liquids'. Together they form a unique fingerprint.

Cite this