Natural safety analysis of the spent fuel residual heat removal in loading and storage process of HTR-10

Jin Hua Wang*, Yi Fan Huang, Yong Tang, Bin Wu

*Corresponding author for this work

Research output: Contribution to journalConference articlepeer-review

5 Citations (Scopus)

Abstract

For the 10 MW High Temperature Gas Cooled Reactor (HTR-10), the residual heat of the spent fuel could be removed by natural ventilation in loading process. The spent fuel storage tank could shield radiation; the outside is covered by an iron sleeve, the spent fuel tank would be stored in atmosphere after fully loaded, and the residual heat could be discharged by natural ventilation in interim storage stage. The calculation showed that, the maximum temperature locates in the middle of the fuel pebble bed in the spent fuel tank in loading process and interim storage stage, and the temperature decrease gradually with radial distance, the temperature in the tank body and sleeve is evenly, it is feasible to remove the residual heat of the spent fuel tank by natural ventilation, and in the natural ventilation condition, the temperature of the spent fuel and the tank is lower than the temperature limit, which provides theoretical evidence for the choice of the residual heat removal method in loading process and interim storage stage.

Original languageEnglish
Pages (from-to)227-239
Number of pages13
JournalEnergy Procedia
Volume39
DOIs
Publication statusPublished - 2013
Externally publishedYes
Event3rd International Conference on Asian Nuclear Prospects, ANUP 2012 - Beijing, China
Duration: 16 Oct 201219 Oct 2012

Keywords

  • High Temperature Gas Cooled Reactor
  • Interim storage
  • Loading
  • Natural ventilation
  • Numerical calculation
  • Spent fuel
  • Storage tank

Fingerprint

Dive into the research topics of 'Natural safety analysis of the spent fuel residual heat removal in loading and storage process of HTR-10'. Together they form a unique fingerprint.

Cite this