Fragment Velocity Test System Based on PVDF

Xuanquan Wang, Ping Song*, Yayu Zhai, Xiaoxiao Chen

*Corresponding author for this work

Research output: Contribution to journalConference articlepeer-review

Abstract

In order to solve the problem of low measurement accuracy, large environmental interference and high cost of production in fragment velocity test, this paper proposed the fragment velocity test system by using PVDF piezoelectric film, NI-PXI platform and LabVIEW graphical programming language. The test system mainly includes PVDF film, adjusting circuit, acquisition module and terminal control software. The adjusting circuit amplifies the weak signal of the PVDF sensor. The acquisition module is responsible for reading the data collected by the data acquisition card for subsequent analysis and storage. The terminal control software executes data multi-channel acquisition, storage and display. The test system is stable and reliable with high accuracy through experimental verification.

Original languageEnglish
Article number012041
JournalIOP Conference Series: Materials Science and Engineering
Volume542
Issue number1
DOIs
Publication statusPublished - 5 Jul 2019
Event2018 International Conference on Mechanical Engineering, Materials Science and Civil Engineering, ICMEMSCE 2018 - Xiamen, China
Duration: 21 Dec 201822 Dec 2018

Keywords

  • Fragment Velocity
  • LabVIEW
  • PVDF Film
  • PXI Platform

Fingerprint

Dive into the research topics of 'Fragment Velocity Test System Based on PVDF'. Together they form a unique fingerprint.