Abstract
Coal spontaneous combustion (CSC) seriously threatens the safety of coal mines. To reduce the spontaneous combustion risk of residual oxidized coal in goaf near coal seam and thick coal seam, it is necessary to study the re-ignition process of coal in depth. The re-ignition process of bituminous coal under different pre-oxidation temperatures and air volume rates was tested by temperature-programmed experiments. The gas index and re-ignition characteristic parameters of low-temperature oxidized coal were analyzed. The results show that CO production, C2H4 concentration, and Graham's fire coefficient (R2, R3) can be used as indicator gases to predict the CSC process. Meanwhile, the oxygen consumption rate and heat release intensity of raw coal and oxidized coal have a good exponential relationship with the coal temperature. In addition, during the slow oxidation stage of bituminous coal, the pre-oxidation process and the increased air volume can increase the oxygen consumption and heat release and reduce the activation energy, which aggravates the risk of spontaneous combustion. The results can enrich the research on the re-ignition characteristics of oxidized coal and can be applied to the management and control of CSC.
Original language | English |
---|---|
Article number | 126124 |
Journal | Energy |
Volume | 265 |
DOIs | |
Publication status | Published - 15 Feb 2023 |
Keywords
- Activation energy
- Air volume
- Heat release intensity
- Indicator gas
- Oxygen consumption
- Pre-oxidation