TY - JOUR
T1 - Direct analysis of melamine in complex matrices using a handheld mass spectrometer
AU - Huang, Guangming
AU - Xu, Wei
AU - Visbal-Onufrak, Michelle A.
AU - Ouyang, Zheng
AU - Cooks, R. Graham
PY - 2010
Y1 - 2010
N2 - A low temperature plasma ambient ionization source, coupled to a portable mass spectrometer (Mini 10.5), is used for the determination of melamine contamination in whole milk and related materials. Thermally assisted desorption and ionization of the analyte was achieved with the plasma probe. The small size, low power consumption and capability for direct sampling without pretreatment makes plasma ionization an appropriate ionization method for use with a handheld mass spectrometer. The standard discontinuous atmospheric pressure interface used to connect atmospheric pressure ion sources to mass spectrometers (Gao et al., Anal. Chem., 2008, 80, 4026-4032) was modified by using supplementary pumping to increase the ion transfer efficiency. Whole milk, fish, milk powder and other complex matrices spiked with melamine were placed on glass slides close to the vacuum inlet and analyzed without sample pretreatment. Quantitation in complex matrices was achieved using MS/MS of protonated melamine m/z 127 to yield the characteristic fragment ion of m/z 85. Analysis rates of two samples per minute, levels of melamine as low as 250 ng/mL in whole milk (below the regulatory level in the US of 1 ppm (1 μg/mL) or the European level of 2.5 ppm (μg/mL)), a linear dynamic range of 0.5-50 μg/mL and a relative standard deviation of ca. 7.6-16.2% were achieved. The importance of melamine to public health and the prior lack of a rapid, sensitive and yet highly specific field analysis method add to the relevance of this study.
AB - A low temperature plasma ambient ionization source, coupled to a portable mass spectrometer (Mini 10.5), is used for the determination of melamine contamination in whole milk and related materials. Thermally assisted desorption and ionization of the analyte was achieved with the plasma probe. The small size, low power consumption and capability for direct sampling without pretreatment makes plasma ionization an appropriate ionization method for use with a handheld mass spectrometer. The standard discontinuous atmospheric pressure interface used to connect atmospheric pressure ion sources to mass spectrometers (Gao et al., Anal. Chem., 2008, 80, 4026-4032) was modified by using supplementary pumping to increase the ion transfer efficiency. Whole milk, fish, milk powder and other complex matrices spiked with melamine were placed on glass slides close to the vacuum inlet and analyzed without sample pretreatment. Quantitation in complex matrices was achieved using MS/MS of protonated melamine m/z 127 to yield the characteristic fragment ion of m/z 85. Analysis rates of two samples per minute, levels of melamine as low as 250 ng/mL in whole milk (below the regulatory level in the US of 1 ppm (1 μg/mL) or the European level of 2.5 ppm (μg/mL)), a linear dynamic range of 0.5-50 μg/mL and a relative standard deviation of ca. 7.6-16.2% were achieved. The importance of melamine to public health and the prior lack of a rapid, sensitive and yet highly specific field analysis method add to the relevance of this study.
UR - http://www.scopus.com/inward/record.url?scp=77949845049&partnerID=8YFLogxK
U2 - 10.1039/b923427f
DO - 10.1039/b923427f
M3 - Article
AN - SCOPUS:77949845049
SN - 0003-2654
VL - 135
SP - 705
EP - 711
JO - The Analyst
JF - The Analyst
IS - 4
ER -