Abstract
An HPLC-UV method was developed and validated for the determination of AKF-PD in whole blood of rat. Phenacetin was chosen as the internal standard, and the separation was achieved on a C18 column with methanol and 0.02 M phosphate buffer (pH 3.2) as mobile phase. The obtained calibration graphs were linear (r = 0.9999, n = 9) in the range of 0.203-52.0 μg ml -1. The low limit of quantitation was 0.203 μg ml-1. This method can be used to study the pharmacokinetics of AKF-PD in rat.
Original language | English |
---|---|
Pages (from-to) | 257-259 |
Number of pages | 3 |
Journal | Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences |
Volume | 833 |
Issue number | 2 |
DOIs | |
Publication status | Published - 3 Apr 2006 |
Externally published | Yes |
Keywords
- AKF-PD
- HPLC
- Pharmacokinetics