Comparison of positive and negative ionic wind in needle-to-plate corona discharge

Jin Song Miao, Yang Chen, Yu Zhang, Zhen Gang Jin

Research output: Contribution to journalArticlepeer-review

7 Citations (Scopus)

Abstract

The needle-to-plate configuration was employed in this paper to investigate the characteristics of ionic wind in corona discharge. The wind velocity and wind pressure were measured experimentally under different conditions including the voltage polarity, the applied voltage, the electrode spacing and the radius of needle tip and so on, to analyze the effect of these factors on ionic wind. The results show that the velocity increases linearly with the over-voltage. Under the same conditions the inception voltage of the positive corona is higher than the negative. The wind velocity of positive corona is higher than the negative at the same over-voltage and electrode spacing. And the polarity effect comes from the difference of developing mechanism between the positive and negative corona.

Original languageEnglish
Pages (from-to)61-66
Number of pages6
JournalBeijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology
Volume37
Issue number1
DOIs
Publication statusPublished - 1 Jan 2017

Keywords

  • Corona discharge
  • Ionic wind
  • Wind velocity