Cardiac rate detection method based on the beam splitter prism

Lei Yang, Xiaohua Liu*, Ming Liu, Yuejin Zhao, Liquan Dong, Ruirui Zhao, Xiaoli Jin, Jingsheng Zhao

*Corresponding author for this work

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

A new cardiac rate measurement method is proposed. Through the beam splitter prism, the common-path optical system of transmitting and receiving signals is achieved. By the focusing effect of the lens, the small amplitude motion artifact is inhibited and the signal-to-noise is improved. The cardiac rate is obtained based on the PhotoPlethysmoGraphy (PPG). We use LED as the light source and use photoelectric diode as the receiving tube. The LED and the photoelectric diode are on the different sides of the beam splitter prism and they form the optical system. The signal processing and display unit is composed by the signal processing circuit, data acquisition device and computer. The light emitted by the modulated LED is collimated by the lens and irradiates the measurement target through the beam splitter prism. The light reflected by the target is focused on the receiving tube through the beam splitter prism and another lens. The signal received by the photoelectric diode is processed by the analog circuit and obtained by the data acquisition device. Through the filtering and Fast Fourier Transform, the cardiac rate is achieved. We get the real time cardiac rate by the moving average method. We experiment with 30 volunteers, containing different genders and different ages. We compare the signals captured by this method to a conventional PPG signal captured concurrently from a finger. The results of the experiments are all relatively agreeable and the biggest deviation value is about 2bmp.

Original languageEnglish
Title of host publicationOptics and Photonics for Information Processing VII
DOIs
Publication statusPublished - 2013
Event7th Conference of Optics and Photonics for Information Processing - San Diego, CA, United States
Duration: 28 Aug 201329 Aug 2013

Publication series

NameProceedings of SPIE - The International Society for Optical Engineering
Volume8855
ISSN (Print)0277-786X
ISSN (Electronic)1996-756X

Conference

Conference7th Conference of Optics and Photonics for Information Processing
Country/TerritoryUnited States
CitySan Diego, CA
Period28/08/1329/08/13

Keywords

  • Beam splitter prism
  • Cardiac rate
  • PhotoPlethysmoGraphy.(PPG)