A new kind of three anastigmatic mirror system

Jun Chang*, Zhi Cheng Weng, Hui Lin Jiang, Yong Tian Wang, Xiao Jie Cong

*Corresponding author for this work

Research output: Contribution to journalConference articlepeer-review

1 Citation (Scopus)

Abstract

This paper describes the results of the design effort for a new kind of three-mirror anastigmatic system (TMAS) and its tolerance exercise. The system's focal length is 100mm and the relative aperture is f/10, it's total length is nearly f'/3∼f'/3.5 and field of view (FOV) is 10 0 × 1 0.The final optical system is a three-mirror unobscured telescope. It achieves diffraction-limited imagery at visible wavelengths. Finally We can draw two conclusions: 1) design of unobscured optical system is still best approached using fundamental optical design principle; 2) time spent in careful modeling of fabrication, testing will result in more relaxed tolerances and a higher probability of success for the assembled system.

Original languageEnglish
Article number45
Pages (from-to)272-275
Number of pages4
JournalProceedings of SPIE - The International Society for Optical Engineering
Volume5638
Issue numberPART 1
DOIs
Publication statusPublished - 2005
EventOptical Design and Testing II - Beijing, United States
Duration: 8 Nov 200411 Nov 2004

Keywords

  • Optical design
  • Tolerance

Fingerprint

Dive into the research topics of 'A new kind of three anastigmatic mirror system'. Together they form a unique fingerprint.

Cite this