Water quality deterioration of reclaimed water produced by reverse osmosis process in large pilot-scale distribution systems of different pipe materials

Xiyan Xu, Yong Cui*, Zhangqing Wang, Hongyu Zhang, Caifeng Li, Kanghua Yu

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

8 引用 (Scopus)

摘要

This work reports the effects of five pipe materials on reverse osmosis (RO)-reclaimed water quality in a large pilot-scale distribution system. These materials includes cast iron (CI), cast iron with cement-mortar lining (CML), stainless steel (SS), PVC, and PE. Long-term running tests for 96 hours are conducted with water quality parameters monitored online and analyzed offline. The results showed that red water appeared in CI pipe due to iron corrosion. The pH and TDS increased during the long-term test. Alkali–silica reaction in CML pipe led to a high increase of pH from 6.3 to 11.4, and TDS from 51 to 230 mg/L. Water quality deterioration was not observed in SS, PVC, and PE pipes. Residual chlorine decay occurred in all the five material pipes with the decay rate order of CI ≫ CML > SS ≈ PVC ≈ PE. Ion concentration variation was also followed during the tests. Fe and Mn ions were detected in CI pipe and Ca, Si, Al, and S were detected in CML pipe. No detectable ion release was found in SS, PVC, and PE pipes. A kinetic model was postulated for the detected ion release with the mechanisms discussed in-depth.

源语言英语
页(从-至)610-620
页数11
期刊Water Reuse
11
4
DOI
出版状态已出版 - 1 12月 2021

指纹

探究 'Water quality deterioration of reclaimed water produced by reverse osmosis process in large pilot-scale distribution systems of different pipe materials' 的科研主题。它们共同构成独一无二的指纹。

引用此