TY - JOUR
T1 - Trace Analysis of Gases and Liquids with Spontaneous Raman Scattering Based on the Integrating Sphere Principle
AU - Huang, Baokun
AU - Zhao, Qiannan
AU - Sun, Chenglin
AU - Zhu, Lin
AU - Zhang, Hong
AU - Zhang, Yunhong
AU - Liu, Cunming
AU - Li, Fabing
N1 - Publisher Copyright:
© 2022 American Chemical Society. All rights reserved.
PY - 2022/10/4
Y1 - 2022/10/4
N2 - Spontaneous Raman scattering is an attractive optical technique for the analysis of gases and liquids; however, their low densities and notoriously weak scattering cross sections demand an enhancement of the spontaneous Raman scattering signal for detection. Here, we have developed a simple but highly effective and fast technique to enhance the signal of spontaneous Raman scattering from gases and liquids. The technique is developed based on the principle of an integrating sphere, which realizes the multiple pass actions of low-energy pump light and the collection of all Raman scattered light for a sample volume of 2 mL. By measuring the ambient air sample with an exposure time of 180 s, we found the experimental detection limit of our spontaneous Raman scattering setup can reach 3 ppm. CH4(<2 ppm) in air can be also examined by increasing the exposure time to 300 s. The performance of our setup used for the analysis of trace gases is further illustrated by characterizing ethane, propane, butane, and pentane in methane as well as isotopes of carbon dioxide. The results reveal that the detection limit of our setup for liquids can be improved by nearly 4 orders of magnitude compared to that of confocal Raman scattering spectroscopy with the same experimental conditions.
AB - Spontaneous Raman scattering is an attractive optical technique for the analysis of gases and liquids; however, their low densities and notoriously weak scattering cross sections demand an enhancement of the spontaneous Raman scattering signal for detection. Here, we have developed a simple but highly effective and fast technique to enhance the signal of spontaneous Raman scattering from gases and liquids. The technique is developed based on the principle of an integrating sphere, which realizes the multiple pass actions of low-energy pump light and the collection of all Raman scattered light for a sample volume of 2 mL. By measuring the ambient air sample with an exposure time of 180 s, we found the experimental detection limit of our spontaneous Raman scattering setup can reach 3 ppm. CH4(<2 ppm) in air can be also examined by increasing the exposure time to 300 s. The performance of our setup used for the analysis of trace gases is further illustrated by characterizing ethane, propane, butane, and pentane in methane as well as isotopes of carbon dioxide. The results reveal that the detection limit of our setup for liquids can be improved by nearly 4 orders of magnitude compared to that of confocal Raman scattering spectroscopy with the same experimental conditions.
UR - http://www.scopus.com/inward/record.url?scp=85139236245&partnerID=8YFLogxK
U2 - 10.1021/acs.analchem.2c03701
DO - 10.1021/acs.analchem.2c03701
M3 - Article
AN - SCOPUS:85139236245
SN - 0003-2700
VL - 94
SP - 13311
EP - 13314
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 39
ER -