TY - JOUR
T1 - Thermodynamic performance of heat pump with R1234ze(E)/R1336mzz(E) binary refrigerant
AU - Hu, Hemin
AU - Wang, Tao
AU - Jiang, Yuyan
AU - Bi, Chao
AU - Zhang, Bing
AU - Fan, Siyi
AU - Li, Jianchao
AU - An, Siyuan
AU - Bai, Xiusen
AU - Guo, Cong
N1 - Publisher Copyright:
© 2023 Elsevier Ltd
PY - 2023/7/25
Y1 - 2023/7/25
N2 - In order to solve the temperature mismatch issue of cold and hot fluids in evaporation and condensation processes for heat pump system, binary refrigerant R1234ze(E)/R1336mzz is recommended in the present research due to its large temperature glide. Through theoretical analysis, multiple configurations under conditions of three different temperature heat sources (70/50 °C, 60/40 °C and 50/30 °C) and two different heat targets (steam above 100 °C and hot water with 70 °C) are constructed adopted Ebsilon code. The optimum mass proportion is obtained as 0.3/0.7 for R1234ze(E)/R1336mzz(E), because of its maximum temperature glide (can reach 21.52 °C) and excellent thermal performance (large COP, ECOP and exergy efficiency). COP of steam high temperature heat pump with R1234ze(E)(0.3)/R1336mzz(E)(0.7) binary refrigerant and the ratio of transferred heat of 110 °C condenser to all output heat (containing 110 °C and 100 °C steam intercooler and condensers) respectively increase up to 67.25% and 335.16% under some certain conditions, compared with that with pure R1336mzz(E). COP of hot water heat pump with R1234ze(E)(0.3)/R1336mzz(E)(0.7) binary refrigerant are respectively 10.31 and 6.89 under 60/40 °C and 50/30 °C heat source conditions, which greatly increases compared with that of heat pump with pure R1234ze(E) (6.67 and 5.03) and R1336mzz(E) (6.74 and 4.54). The present research may lay a foundation for binary refrigerant adoption to replace the scheme of multi-stage evaporator or multi-stage condenser, which could reduce the irreversible loss of phase change equipment and improve thermodynamic performance of heat pumps.
AB - In order to solve the temperature mismatch issue of cold and hot fluids in evaporation and condensation processes for heat pump system, binary refrigerant R1234ze(E)/R1336mzz is recommended in the present research due to its large temperature glide. Through theoretical analysis, multiple configurations under conditions of three different temperature heat sources (70/50 °C, 60/40 °C and 50/30 °C) and two different heat targets (steam above 100 °C and hot water with 70 °C) are constructed adopted Ebsilon code. The optimum mass proportion is obtained as 0.3/0.7 for R1234ze(E)/R1336mzz(E), because of its maximum temperature glide (can reach 21.52 °C) and excellent thermal performance (large COP, ECOP and exergy efficiency). COP of steam high temperature heat pump with R1234ze(E)(0.3)/R1336mzz(E)(0.7) binary refrigerant and the ratio of transferred heat of 110 °C condenser to all output heat (containing 110 °C and 100 °C steam intercooler and condensers) respectively increase up to 67.25% and 335.16% under some certain conditions, compared with that with pure R1336mzz(E). COP of hot water heat pump with R1234ze(E)(0.3)/R1336mzz(E)(0.7) binary refrigerant are respectively 10.31 and 6.89 under 60/40 °C and 50/30 °C heat source conditions, which greatly increases compared with that of heat pump with pure R1234ze(E) (6.67 and 5.03) and R1336mzz(E) (6.74 and 4.54). The present research may lay a foundation for binary refrigerant adoption to replace the scheme of multi-stage evaporator or multi-stage condenser, which could reduce the irreversible loss of phase change equipment and improve thermodynamic performance of heat pumps.
KW - Binary refrigerant
KW - Heat pump
KW - R1234ze(E) / R1336mzz
KW - Temperature glide
KW - Thermodynamic performance
UR - http://www.scopus.com/inward/record.url?scp=85160099210&partnerID=8YFLogxK
U2 - 10.1016/j.applthermaleng.2023.120795
DO - 10.1016/j.applthermaleng.2023.120795
M3 - Article
AN - SCOPUS:85160099210
SN - 1359-4311
VL - 230
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
M1 - 120795
ER -