TY - JOUR
T1 - The novel copolymer coated capillary columns of electrophoresis and their applications to separation of proteins
AU - Lu, G.
AU - Gao, D.
AU - Gu, J.
AU - Fu, R.
AU - Li, F.
AU - Zhang, H.
PY - 1999/1
Y1 - 1999/1
N2 - The copolymer of acrylonitrile, methyl acrylate, hydroxy ethyl acrylate (ZB-004), the copolymer of acrylonitrile, methyl acrylate, hydroxy ethyl acrylate, acrylamide (ZB-014) and the copolymer of acrylonitrile, hydroxy ethyl acrylate (ZB-016) were coated on the inner surface of fused-silica capillaries by just filling the capillary with solutions containing these copolymers followed by flushing the capillary with nitrogen. The physically adsorbed layer can reduce both protein adsorption and electroosmotic flow in the pH range of 3-5. Electroosmotic flow decreased by raising the concentrations of the copolymers. Separation performance of ZB-004 layer is better than those of other two layers due to its low hydrophilicity, but with higher pH values, appreciable peak deformation and increase in electroosmosis were observed. The intra day and inter day migration reproducibility were investigated in terms of relative standard deviation (RSD) with four basic proteins at pH 4.0. The RSDs of the intra day migration times were less than 2%. The RSDs of the inter day migration times were less than 4%. At pH 5.0, the RSDs of the migration times in two ZB-004-coated capillaries made on two different days were less than 1%. Separation efficiencies of four basic proteins in a ZB-004-coated capillary which stored in a buffer (pH 4.0) for fifteen days after being used for 14 days decreased 15%. These coatings were stable and exhibited reproducible separations from intra day, inter day and inter column under acidic conditions.
AB - The copolymer of acrylonitrile, methyl acrylate, hydroxy ethyl acrylate (ZB-004), the copolymer of acrylonitrile, methyl acrylate, hydroxy ethyl acrylate, acrylamide (ZB-014) and the copolymer of acrylonitrile, hydroxy ethyl acrylate (ZB-016) were coated on the inner surface of fused-silica capillaries by just filling the capillary with solutions containing these copolymers followed by flushing the capillary with nitrogen. The physically adsorbed layer can reduce both protein adsorption and electroosmotic flow in the pH range of 3-5. Electroosmotic flow decreased by raising the concentrations of the copolymers. Separation performance of ZB-004 layer is better than those of other two layers due to its low hydrophilicity, but with higher pH values, appreciable peak deformation and increase in electroosmosis were observed. The intra day and inter day migration reproducibility were investigated in terms of relative standard deviation (RSD) with four basic proteins at pH 4.0. The RSDs of the intra day migration times were less than 2%. The RSDs of the inter day migration times were less than 4%. At pH 5.0, the RSDs of the migration times in two ZB-004-coated capillaries made on two different days were less than 1%. Separation efficiencies of four basic proteins in a ZB-004-coated capillary which stored in a buffer (pH 4.0) for fifteen days after being used for 14 days decreased 15%. These coatings were stable and exhibited reproducible separations from intra day, inter day and inter column under acidic conditions.
UR - http://www.scopus.com/inward/record.url?scp=0038041965&partnerID=8YFLogxK
M3 - Article
C2 - 12548833
AN - SCOPUS:0038041965
SN - 1000-8713
VL - 17
SP - 64
EP - 66
JO - Chinese Journal of Chromatography (Se Pu)
JF - Chinese Journal of Chromatography (Se Pu)
IS - 1
ER -