TY - JOUR
T1 - The modulate chopper technique used in pyroelectric uncooled focal plane array thermal imager
AU - He, Yuqing
AU - Jin, Weiqi
AU - Liu, Guangrong
AU - Gao, Zhiyun
AU - Wang, Xia
AU - Wang, Lingxue
PY - 2002
Y1 - 2002
N2 - Pyroelectric uncooled focal plane array (FPA) thermal imager has the advantages of low cost, small size, high responsibility and can work under room temperature, so it has great progress in recent years. As a matched technique, the modulate chopper has become one of the key techniques in uncooled FPA thermal imaging system. Now the Archimedes spiral cord chopper technique is mostly used. When it works, the chopper pushing scans the detector's pixel array, thus makes the pixels being exposed continuously. This paper simulates the shape of this kind of chopper, analyses the exposure time of the detector's every pixel, and also analyses the whole detector pixels' exposure sequence. From the analysis we can get the results: the parameter of Archimedes spiral cord, the detector's thermal time constant, the detector's geometrical dimension, the relative position of the detector to the chopper's spiral cord are the system's important parameters, they will affect the chopper's exposure efficiency and uniformity. We should design the chopper's relevant parameter according to the practical request to achieve the chopper's appropriate structure.
AB - Pyroelectric uncooled focal plane array (FPA) thermal imager has the advantages of low cost, small size, high responsibility and can work under room temperature, so it has great progress in recent years. As a matched technique, the modulate chopper has become one of the key techniques in uncooled FPA thermal imaging system. Now the Archimedes spiral cord chopper technique is mostly used. When it works, the chopper pushing scans the detector's pixel array, thus makes the pixels being exposed continuously. This paper simulates the shape of this kind of chopper, analyses the exposure time of the detector's every pixel, and also analyses the whole detector pixels' exposure sequence. From the analysis we can get the results: the parameter of Archimedes spiral cord, the detector's thermal time constant, the detector's geometrical dimension, the relative position of the detector to the chopper's spiral cord are the system's important parameters, they will affect the chopper's exposure efficiency and uniformity. We should design the chopper's relevant parameter according to the practical request to achieve the chopper's appropriate structure.
KW - Archimedes spiral cord
KW - FPA detector
KW - Modulate chopper
KW - Pyroelectric
UR - http://www.scopus.com/inward/record.url?scp=0036442143&partnerID=8YFLogxK
U2 - 10.1117/12.471869
DO - 10.1117/12.471869
M3 - Conference article
AN - SCOPUS:0036442143
SN - 0277-786X
VL - 4919
SP - 283
EP - 288
JO - Proceedings of SPIE - The International Society for Optical Engineering
JF - Proceedings of SPIE - The International Society for Optical Engineering
T2 - Advanced Materials and Devices for Sensing and Imaging
Y2 - 17 October 2002 through 18 October 2002
ER -