摘要
The problems possibly occurred in the coal bed methane (CBM) well measurement are analyzed. An extrinsic Fabry Perot (F-P) interferometer (EFPI) is used as a new direction of liquid surface measurement in coal bed methane well. A liquid surface measuring system on the EFPI is developed to fundamentally solve the difficult problems of the accurate level in the coal bed methane well. The relative error of optical cavity length is 1.48% and resolution is 1 μm in the measuring system, which is obviously more effective than the traditional measuring technologies.
源语言 | 英语 |
---|---|
页(从-至) | 442-444 |
页数 | 3 |
期刊 | Guangxue Jishu/Optical Technique |
卷 | 41 |
期 | 5 |
出版状态 | 已出版 - 1 9月 2015 |
指纹
探究 'The fiber-optic technique for the measurement of the liquid surface in coal bed methane well' 的科研主题。它们共同构成独一无二的指纹。引用此
Li, L., Jiang, Y., & Liu, Y. (2015). The fiber-optic technique for the measurement of the liquid surface in coal bed methane well. Guangxue Jishu/Optical Technique, 41(5), 442-444.