摘要
Background: Knee osteoarthritis (OA) is suggested to be induced by multi-factors, and mechanical environment is regarded as a risky factor. Objective: To investigate the effect of isolated mechanical factor on cartilage. Methods: An active wear test system was designed to perform parameters-controlled in vitro wear tests on rat knee joints with specific load magnitude, flexion-extension angle, and movement frequency. Six hind limbs of 9-month-old male Sprague- Dawley rats, with an additional spring on the medial side, were worn by using the custom-designed apparatus. Researchers observed both the menisci and tibial cartilages of these hind limbs using multiphoton laser scanning microscopy to analyze the change of the collagen microstructure caused by wear. Results: Collagen microstructure of both the medial and lateral meniscus became disordered under cyclic load. Some tissues on the surface of the medial tibial cartilage were removed and the middle layer of the medial compartment displayed cracks. On the contrary, the lateral tibial cartilage was intact. Conclusions: The results implied that cyclic load caused menisci microstructure disarrangement prior to tibial cartilage damage and the collagen structure of mid-layer tibial cartilage failed before that of the superficial layer under the kinematics adopted in the study.
源语言 | 英语 |
---|---|
页(从-至) | S207-S217 |
期刊 | Technology and Health Care |
卷 | 25 |
期 | S1 |
DOI | |
出版状态 | 已出版 - 21 7月 2017 |
已对外发布 | 是 |
活动 | 5th International Conference on Biomedical Engineering and Biotechnology, ICBEB 2016 - Hangzhou, 中国 期限: 1 8月 2016 → 4 8月 2016 |