TY - JOUR
T1 - Temperature field of body surface measurement by uncooled infrared thermal imager and error correction
AU - Zhang, Xiaoye
AU - Xu, Chao
AU - He, Limin
AU - Chen, Yihe
N1 - Publisher Copyright:
© 2016, Editorial Board of Journal of Infrared and Laser Engineering. All right reserved.
PY - 2016/10/25
Y1 - 2016/10/25
N2 - Measure body surface temperature with uncooled infrared thermal imager has many features such as fast, non-contact, short scope of measurement and higher accuracy requirement. But temperature of core and environment will interfere the accuracy of micro-bolometer to a great degree. A new method was proposed to correct temperature error caused by the difference of temperature between calibration and measurement. The data of core temperature, environment temperature and grayscale were measured and recorded, and then error correction parameter was calculated by using SVM. In the course of measurement, the environment temperature and core temperature were obtained with thermocouple and sensor in micro-bolometer, and then error correction of environment temperature and core temperature were finished by error correction parameter. By this way more accurate data of human body surface temperature field were gained. Experimental results shows that the error of new corrected method can be decreased at least 50% when the distance of measurement is about 2m, compared with thermocouple of high precision which had been calibrated.
AB - Measure body surface temperature with uncooled infrared thermal imager has many features such as fast, non-contact, short scope of measurement and higher accuracy requirement. But temperature of core and environment will interfere the accuracy of micro-bolometer to a great degree. A new method was proposed to correct temperature error caused by the difference of temperature between calibration and measurement. The data of core temperature, environment temperature and grayscale were measured and recorded, and then error correction parameter was calculated by using SVM. In the course of measurement, the environment temperature and core temperature were obtained with thermocouple and sensor in micro-bolometer, and then error correction of environment temperature and core temperature were finished by error correction parameter. By this way more accurate data of human body surface temperature field were gained. Experimental results shows that the error of new corrected method can be decreased at least 50% when the distance of measurement is about 2m, compared with thermocouple of high precision which had been calibrated.
KW - Body surface temperature field
KW - Core temperature
KW - Environment temperature
KW - Error correction
KW - Uncooled infrared thermal imager
UR - http://www.scopus.com/inward/record.url?scp=84995428181&partnerID=8YFLogxK
U2 - 10.3788/IRLA201645.1004003
DO - 10.3788/IRLA201645.1004003
M3 - Article
AN - SCOPUS:84995428181
SN - 1007-2276
VL - 45
JO - Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering
JF - Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering
IS - 10
M1 - 1004003
ER -