TY - JOUR
T1 - Techno-economic analysis on frosting/defrosting operations for an air source heat pump unit with an optimized multi-circuit outdoor coil
AU - Song, Mengjie
AU - Tso, Chiyan
AU - Chao, Christopher Yuhang
AU - Wu, Chili
N1 - Publisher Copyright:
© 2018 Elsevier B.V.
PY - 2018/5/1
Y1 - 2018/5/1
N2 - Air source heat pump (ASHP) units are used in applications around the world. After optimizing the multi-circuit outdoor coil by installing water collecting trays between circuits and adjusting the refrigerant distribution by using valves located at each circuit, system frosting/defrosting operation performances could be effectively improved. Before practical industry-scale application of trays and valves, their economic performances should be evaluated. However, in current literature, techno-economic analysis on operation performance of ASHP units is rare, which limits the development of innovative technologies. Therefore, a techno-economic analysis on frosting/defrosting operations is carried out in this study. Firstly, the frosting/defrosting experiments are introduced, followed by a series of assumptions and calculations. Then, the economic analysis results are provided in detail. Compared with a traditional ASHP unit, the total running costs of the modified unit in the heating season could save as much as 3681.75 CNY, or 10.33%, and the total cost decreased by 3516.75 CNY, or 4.67%, over 15 years of service life. The payback period of the additional initial cost is less than 8 months. Contribution of this work plays an important role in the evaluation and application of new technologies in the HVAC field.
AB - Air source heat pump (ASHP) units are used in applications around the world. After optimizing the multi-circuit outdoor coil by installing water collecting trays between circuits and adjusting the refrigerant distribution by using valves located at each circuit, system frosting/defrosting operation performances could be effectively improved. Before practical industry-scale application of trays and valves, their economic performances should be evaluated. However, in current literature, techno-economic analysis on operation performance of ASHP units is rare, which limits the development of innovative technologies. Therefore, a techno-economic analysis on frosting/defrosting operations is carried out in this study. Firstly, the frosting/defrosting experiments are introduced, followed by a series of assumptions and calculations. Then, the economic analysis results are provided in detail. Compared with a traditional ASHP unit, the total running costs of the modified unit in the heating season could save as much as 3681.75 CNY, or 10.33%, and the total cost decreased by 3516.75 CNY, or 4.67%, over 15 years of service life. The payback period of the additional initial cost is less than 8 months. Contribution of this work plays an important role in the evaluation and application of new technologies in the HVAC field.
KW - Air source heat pump
KW - Frosting/defrosting operation
KW - Multi-circuit outdoor coil
KW - Payback period
KW - Techno-economic analysis
UR - http://www.scopus.com/inward/record.url?scp=85042227589&partnerID=8YFLogxK
U2 - 10.1016/j.enbuild.2018.01.060
DO - 10.1016/j.enbuild.2018.01.060
M3 - Article
AN - SCOPUS:85042227589
SN - 0378-7788
VL - 166
SP - 165
EP - 177
JO - Energy and Buildings
JF - Energy and Buildings
ER -