Study on treatment tobacco odor with non-thermal plasma technology

Tao Zhu*, Jian Li, Bao Juan Dou, Wen Jun Liang, Yu Quan Jin

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

6 引用 (Scopus)

摘要

Odor smell from tobacco processing is a kind of odor pollution. Air emitted from Shanghai Cigarette Plant reached secondary standard of environment air quality (GB3095-96) by using non-thermal plasma technology. The experiment also put forward the basis for increasing removal efficiency of non-thermal plasma facility. In the laboratory, electric field strength and gas flow velocity were changed. The results showed removal efficiency of tobacco odor increased with electric field strength increasing and gas flow velocity decreasing. As important factors for design NPTS (non-thermal plasma treatment system), rest time was 1-2 s and electric field strength was above 10 kV/cm, which should be selected. In the cigarette plant's experiment, gas flux and equipment power were changed. The results showed that the plasma reactor should not be too big, and shunt-wound reactors should be a good application. When equipment power reached 6 kW, removal efficiency of tobacco odor was the highest.

源语言英语
页(从-至)862-866
页数5
期刊Xi'an Jianzhu Keji Daxue Xuebao/Journal of Xi'an University of Architecture & Technology
39
6
出版状态已出版 - 12月 2007