TY - JOUR
T1 - Research on Digitally Integrated Test System for Performance Evaluation of Image Intensifier and Intensified CCD
AU - Wang, Xia
AU - Jin, Weiqi
AU - Gao, Zhiyun
AU - Wang, Zhihong
AU - Bai, Tingzhu
PY - 2006
Y1 - 2006
N2 - Image intensifier and intensified CCD (ICCD) are critical components in the field of night vision technology. There are some specifications, such as luminance uniformity, fixed pattern noise, resolution, modulation transfer function (MTF), etc., which can be used to evaluate the performance of such components. A digitally integrated test system for performance evaluation of image intensifier and ICCD is described in this paper. The system can test 11 specifications for imaging intensifier (generation 1, 2 and 3) and ICCD with some essential accessories. The system operation theory, structure and testing results are represented in detail. The system has been run at North Night Vision Technology Co. for about 10 months. The results after long running period are given. And the factors that affect the measurement accuracy are analyzed. The results show that the digitally integral system has high measurement precision and stability.
AB - Image intensifier and intensified CCD (ICCD) are critical components in the field of night vision technology. There are some specifications, such as luminance uniformity, fixed pattern noise, resolution, modulation transfer function (MTF), etc., which can be used to evaluate the performance of such components. A digitally integrated test system for performance evaluation of image intensifier and ICCD is described in this paper. The system can test 11 specifications for imaging intensifier (generation 1, 2 and 3) and ICCD with some essential accessories. The system operation theory, structure and testing results are represented in detail. The system has been run at North Night Vision Technology Co. for about 10 months. The results after long running period are given. And the factors that affect the measurement accuracy are analyzed. The results show that the digitally integral system has high measurement precision and stability.
KW - Digitized integral test
KW - ICCD
KW - Image intensifier
KW - Performance measurement
KW - SLM
KW - Wide illuminance range
UR - http://www.scopus.com/inward/record.url?scp=33645276845&partnerID=8YFLogxK
U2 - 10.1117/12.678099
DO - 10.1117/12.678099
M3 - Conference article
AN - SCOPUS:33645276845
SN - 0277-786X
VL - 6150 I
JO - Proceedings of SPIE - The International Society for Optical Engineering
JF - Proceedings of SPIE - The International Society for Optical Engineering
M1 - 61500S
T2 - 2nd International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment
Y2 - 2 November 2005 through 5 November 2005