Relationship between integral time and two-point non-uniform correction for HDR imaging of cooled focal plane array

Xiong Dun, Yong Jie Fan, Wei Qi Jin, Xia Wang

科研成果: 期刊稿件文章同行评审

3 引用 (Scopus)

摘要

Variable integral time is an effective means to realize the high dynamic range (HDR) of infrared system. Unfortunately, it would lead to serious residual non-uniformity. The relationship between the correction parameters (gain and offset) of two-point non-uniform correction (NUC) and integral time is derived based on the infrared system response model. The result shows that the gain parameters are independent of integral time, and only the bias parameters change with integral time. The correctness of the above conclusions is confirmed by testing it against standard two-point NUC method. The result can provide a reasonable evidence for NUC of infrared system with variable integral time, which only updates the offset parameters but maintain same gain parameters.

源语言英语
页(从-至)839-845
页数7
期刊Binggong Xuebao/Acta Armamentarii
36
5
DOI
出版状态已出版 - 1 5月 2015

指纹

探究 'Relationship between integral time and two-point non-uniform correction for HDR imaging of cooled focal plane array' 的科研主题。它们共同构成独一无二的指纹。

引用此