Optimal Continuous Glucose Monitoring Sensor Calibration for Patients with Type 1 Diabetes

Xiaoran Zhang, Wan Zhang, Yongtong Cao, Dawei Shi*, Ling Shi

*此作品的通讯作者

科研成果: 书/报告/会议事项章节会议稿件同行评审

摘要

The calibration of continuous glucose monitoring (CGM) devices is clinically important due to its role in accurate glucose supervision for diabetic patients. However, the calibration is often performed by finger pricks measurement, which adds patients discomfort while already suffering from diabetes. Therefore, reducing the frequency of finger pricks with undiminished CGM sensor accuracy is essential to improve the patients living condition. In this paper, we aim to propose a fully automated approach for CGM sensor calibration and reduce finger prick frequency. A novel framework is designed and we utilize an unknown input observer to delineate the Blood Glucose (BG)-Interstitial Glucose (IG) relation. We also propose a new cost function with a regularization parameter for sensor parameter estimation. The proposed algorithm is evaluated on the FDA-accepted UVA/Padova T1DM simulator and compared with the original calibration. The meals are designed with various volumes of carbohydrate to simulate the patients' daily intake. The optimal result among all scenarios using mean absolute relative deviation (MARD) metric is 0.10% for 1 calibration (cal) per day while 3.39% for original calibration on the same frequency. After reducing the finger pricks frequency, the results only increase 0.01% and 0.04% using MARD metric for 1 cal/2 days and 1 cal/4 days respectively.

源语言英语
主期刊名Proceedings - 2019 IEEE 28th International Symposium on Industrial Electronics, ISIE 2019
出版商Institute of Electrical and Electronics Engineers Inc.
617-622
页数6
ISBN(电子版)9781728136660
DOI
出版状态已出版 - 6月 2019
活动28th IEEE International Symposium on Industrial Electronics, ISIE 2019 - Vancouver, 加拿大
期限: 12 6月 201914 6月 2019

出版系列

姓名IEEE International Symposium on Industrial Electronics
2019-June

会议

会议28th IEEE International Symposium on Industrial Electronics, ISIE 2019
国家/地区加拿大
Vancouver
时期12/06/1914/06/19

指纹

探究 'Optimal Continuous Glucose Monitoring Sensor Calibration for Patients with Type 1 Diabetes' 的科研主题。它们共同构成独一无二的指纹。

引用此