摘要
A near-field imaging method based on the Non-uniform fast Fourier transformation (NUFFT) is presented. The NUFFT is incorporated in the computed tomography (CT) method in replace of the inverse fast Fourier transformation (IFFT) and the one-dimensional (1-D) interpolation. Comparisons with the conventional near-field filtered back projection (FBP) method are performed. Simulations demonstrate that the NUFFT-based near-field imaging method shows higher precision and lower side-lobes than the FBP method.
源语言 | 英语 |
---|---|
主期刊名 | ICMTCE2011 - Proceedings 2011 IEEE International Conference on Microwave Technology and Computational Electromagnetics |
页 | 104-106 |
页数 | 3 |
DOI | |
出版状态 | 已出版 - 2011 |
活动 | 2011 2nd IEEE International Conference on Microwave Technology and Computational Electromagnetics, ICMTCE2011 - Beijing, 中国 期限: 22 5月 2011 → 25 5月 2011 |
出版系列
姓名 | ICMTCE2011 - Proceedings 2011 IEEE International Conference on Microwave Technology and Computational Electromagnetics |
---|
会议
会议 | 2011 2nd IEEE International Conference on Microwave Technology and Computational Electromagnetics, ICMTCE2011 |
---|---|
国家/地区 | 中国 |
市 | Beijing |
时期 | 22/05/11 → 25/05/11 |
指纹
探究 'NUFFT-based near-field imaging method for target scattering diagnostics' 的科研主题。它们共同构成独一无二的指纹。引用此
Zhao, G., Li, S., Zhang, Z., & Liu, B. (2011). NUFFT-based near-field imaging method for target scattering diagnostics. 在 ICMTCE2011 - Proceedings 2011 IEEE International Conference on Microwave Technology and Computational Electromagnetics (页码 104-106). 文章 5915174 (ICMTCE2011 - Proceedings 2011 IEEE International Conference on Microwave Technology and Computational Electromagnetics). https://doi.org/10.1109/ICMTCE.2011.5915174