TY - JOUR
T1 - Non-axisymmetric phenomenon of shroud pressure and tip leakage in the centrifugal compressor
AU - Zhu, Qinglin
AU - Lao, Dazhong
AU - Wang, Leilei
AU - Yang, Ce
N1 - Publisher Copyright:
© 2016, Editorial Office of the Transaction of CSICE. All right reserved.
PY - 2016/9/25
Y1 - 2016/9/25
N2 - Volutes are usually designed to be the spiral configuration.The circumferential distortion induced by the circumferential non-uniform geometric structure of volute has significant influence on compressor internal flow field.Experimental and numerical approaches were used to study the non-axisymmetric flow characteristics in a compressor under two mass flow conditions.Results show that the compressor shroud static pressure distributions in the circumferential direction maintain the same characteristics of axisymmetric distortion form in volute.In the process of reverse transmission of downstream flow field distortion to the upstream,its impact on the upstream is gradually weakening.When shroud circumferential high pressure zone of the impeller outlet spreads to the impeller inlet,it appears phase difference to that of the impeller outlet high circumferential position.Under different mass flow conditions, the static pressure's non-uniform distribution leads to the differences of the circumferential distribution of the blade tip leakage flow.Under small mass flow condition,the leakage flow shows a decreasing,and then increasing and late decreasing.Under large mass flow condition,the leakage flow shows an increasing and then keeps the continuous decreasing.
AB - Volutes are usually designed to be the spiral configuration.The circumferential distortion induced by the circumferential non-uniform geometric structure of volute has significant influence on compressor internal flow field.Experimental and numerical approaches were used to study the non-axisymmetric flow characteristics in a compressor under two mass flow conditions.Results show that the compressor shroud static pressure distributions in the circumferential direction maintain the same characteristics of axisymmetric distortion form in volute.In the process of reverse transmission of downstream flow field distortion to the upstream,its impact on the upstream is gradually weakening.When shroud circumferential high pressure zone of the impeller outlet spreads to the impeller inlet,it appears phase difference to that of the impeller outlet high circumferential position.Under different mass flow conditions, the static pressure's non-uniform distribution leads to the differences of the circumferential distribution of the blade tip leakage flow.Under small mass flow condition,the leakage flow shows a decreasing,and then increasing and late decreasing.Under large mass flow condition,the leakage flow shows an increasing and then keeps the continuous decreasing.
KW - Centrifugal compressor
KW - Non-axisymmetry
KW - Static pressure distortion
KW - Tip leakage flow
UR - http://www.scopus.com/inward/record.url?scp=84992512228&partnerID=8YFLogxK
U2 - 10.16236/j.cnki.nrjxb.201605064
DO - 10.16236/j.cnki.nrjxb.201605064
M3 - Article
AN - SCOPUS:84992512228
SN - 1000-0909
VL - 34
SP - 463
EP - 472
JO - Neiranji Xuebao/Transactions of CSICE (Chinese Society for Internal Combustion Engines)
JF - Neiranji Xuebao/Transactions of CSICE (Chinese Society for Internal Combustion Engines)
IS - 5
ER -