摘要
For the 10 MW High Temperature Gas Cooled Reactor (HTR-10), the residual heat of the spent fuel could be removed by natural ventilation in loading process. The spent fuel storage tank could shield radiation; the outside is covered by an iron sleeve, the spent fuel tank would be stored in atmosphere after fully loaded, and the residual heat could be discharged by natural ventilation in interim storage stage. The calculation showed that, the maximum temperature locates in the middle of the fuel pebble bed in the spent fuel tank in loading process and interim storage stage, and the temperature decrease gradually with radial distance, the temperature in the tank body and sleeve is evenly, it is feasible to remove the residual heat of the spent fuel tank by natural ventilation, and in the natural ventilation condition, the temperature of the spent fuel and the tank is lower than the temperature limit, which provides theoretical evidence for the choice of the residual heat removal method in loading process and interim storage stage.
源语言 | 英语 |
---|---|
页(从-至) | 227-239 |
页数 | 13 |
期刊 | Energy Procedia |
卷 | 39 |
DOI | |
出版状态 | 已出版 - 2013 |
已对外发布 | 是 |
活动 | 3rd International Conference on Asian Nuclear Prospects, ANUP 2012 - Beijing, 中国 期限: 16 10月 2012 → 19 10月 2012 |