TY - JOUR
T1 - Myocardial late gadolinium enhancement
T2 - a head-to-head comparison of motion-corrected balanced steady-state free precession with segmented turbo fast low angle shot
AU - Fan, H.
AU - Li, S.
AU - Lu, M.
AU - Yin, G.
AU - Yang, X.
AU - Lan, T.
AU - Dai, L.
AU - Chen, X.
AU - Li, J.
AU - Zhang, Y.
AU - Sirajuddin, A.
AU - Kellman, P.
AU - Arai, A. E.
AU - Zhao, S.
N1 - Publisher Copyright:
© 2018 The Royal College of Radiologists
PY - 2018/6
Y1 - 2018/6
N2 - Aim: To evaluate the image quality and diagnostic agreement with a head-to-head comparison of late gadolinium enhancement (LGE) images acquired by the motion-corrected (MOCO) balanced steady-state free precession (bSSFP) phase sensitivity inversion recovery (PSIR) and conventional segmented fast low angle shot (FLASH) PSIR methods15,16 in a patient cohort with a wide spectrum of cardiovascular disease. Materials and methods: In 59 consecutive patients, signal-to-noise ratios (SNRs), contrast-to-noise ratios (CNRs) of the normal myocardium (NM), LGE, and blood pool (BP) were pair-wise compared between the two different sequences. A further semi-qualitative score system (graded 1 –4) was used to compare the overall image quality (OIQ). The diagnostic agreement of the two techniques were evaluated by both transmural severity and absolutely quantitative size of LGE. Results: The SNRs of the NM, LGE, and BP of MOCO bSSFP were 4.8±3.4, 53.6±35.6 and 43.2±29.3, compared with 3.9±3.6 (p=0.126), 27.7±18.5 (p<0.001) and 24.3±13.4 (p<0.001) of FLASH LGE, respectively. The CNRs of LGE to NM, LGE to BP, and BP to NM were 48.3±33.1 versus 23.8±16.7 (p<0.001), 6.5±21.6 versus 3.8±10.8 (p<0.001), and 38.3±27.2 versus 20.3±10.7 (p=0.448), respectively. The OIQ of MOCO bSSFP was higher than that of segmented FLASH (median 4 versus median 3, p<0.001). For quantification of LGE size, there is good agreement and high correlation (r=0.992, p<0.001) between the two methods. Conclusions: MOCO bSSFP is a feasible, robust sequence for LGE imaging, especially for patients with arrhythmia and those incapable of breath-holding due to severe heart failure.
AB - Aim: To evaluate the image quality and diagnostic agreement with a head-to-head comparison of late gadolinium enhancement (LGE) images acquired by the motion-corrected (MOCO) balanced steady-state free precession (bSSFP) phase sensitivity inversion recovery (PSIR) and conventional segmented fast low angle shot (FLASH) PSIR methods15,16 in a patient cohort with a wide spectrum of cardiovascular disease. Materials and methods: In 59 consecutive patients, signal-to-noise ratios (SNRs), contrast-to-noise ratios (CNRs) of the normal myocardium (NM), LGE, and blood pool (BP) were pair-wise compared between the two different sequences. A further semi-qualitative score system (graded 1 –4) was used to compare the overall image quality (OIQ). The diagnostic agreement of the two techniques were evaluated by both transmural severity and absolutely quantitative size of LGE. Results: The SNRs of the NM, LGE, and BP of MOCO bSSFP were 4.8±3.4, 53.6±35.6 and 43.2±29.3, compared with 3.9±3.6 (p=0.126), 27.7±18.5 (p<0.001) and 24.3±13.4 (p<0.001) of FLASH LGE, respectively. The CNRs of LGE to NM, LGE to BP, and BP to NM were 48.3±33.1 versus 23.8±16.7 (p<0.001), 6.5±21.6 versus 3.8±10.8 (p<0.001), and 38.3±27.2 versus 20.3±10.7 (p=0.448), respectively. The OIQ of MOCO bSSFP was higher than that of segmented FLASH (median 4 versus median 3, p<0.001). For quantification of LGE size, there is good agreement and high correlation (r=0.992, p<0.001) between the two methods. Conclusions: MOCO bSSFP is a feasible, robust sequence for LGE imaging, especially for patients with arrhythmia and those incapable of breath-holding due to severe heart failure.
UR - http://www.scopus.com/inward/record.url?scp=85043496670&partnerID=8YFLogxK
U2 - 10.1016/j.crad.2018.02.002
DO - 10.1016/j.crad.2018.02.002
M3 - Article
C2 - 29548551
AN - SCOPUS:85043496670
SN - 0009-9260
VL - 73
SP - 593.e1-593.e9
JO - Clinical Radiology
JF - Clinical Radiology
IS - 6
ER -