Modulation transfer function evaluation of charge-coupled-device camera system based on liquid crystal display random targets

Xusheng Zhang*, Dingguo Sha

*此作品的通讯作者

科研成果: 期刊稿件会议文章同行评审

3 引用 (Scopus)

摘要

In order to overcome the sampling-scene phase effect in the modulation transfer function (MTF) measurement of sampled imaging systems, a method using a pseudorandom number generating algorithm to generate several random targets displayed on a liquid-crystal-display(LCD) graph generator to evaluate the MTF of charge-coupled device(CCD) in visible region is discussed. The major advantages of this technique are that it has been demonstrated as a shift-invariant method without requiring mechanical scanning, and it is easy to generate a large number of random targets on LCD by computer program to get the average result and reduce measurement noise. By experiments, this technique has got a reliable MTF result and agrees with the usual methods. This method is expected to be used to develop a real-time video MTF testing software system.

源语言英语
文章编号183
页(从-至)1014-1021
页数8
期刊Proceedings of SPIE - The International Society for Optical Engineering
5638
PART 2
DOI
出版状态已出版 - 2005
活动Optical Design and Testing II - Beijing, 美国
期限: 8 11月 200411 11月 2004

指纹

探究 'Modulation transfer function evaluation of charge-coupled-device camera system based on liquid crystal display random targets' 的科研主题。它们共同构成独一无二的指纹。