TY - JOUR
T1 - MmHRV
T2 - Contactless Heart Rate Variability Monitoring Using Millimeter-Wave Radio
AU - Wang, Fengyu
AU - Zeng, Xiaolu
AU - Wu, Chenshu
AU - Wang, Beibei
AU - Liu, K. J.Ray
N1 - Publisher Copyright:
© 2014 IEEE.
PY - 2021/11/15
Y1 - 2021/11/15
N2 - Heart rate variability (HRV), which measures the fluctuation of heartbeat intervals, has been considered as an important indicator for general health evaluation. To alleviate the user burden and explore the usability for long-term health monitoring, noncontact methods for HRV monitoring have drawn tremendous attention. In this article, we present mmHRV, the first contact-free multiuser HRV monitoring system using commercial millimeter-wave (mmWave) radio. The design of mmHRV consists of two key components. First, we develop a calibration-free target detector to identify each user's location. Second, a heartbeat signal extractor is devised, which can optimize the decomposition of the phase of the channel information modulated by the chest movement and, thus, estimate the heartbeat signal. The exact time of heartbeats is estimated by finding the peak location of the heartbeat signal while the interbeat intervals (IBIs) can be further derived for evaluating the HRV metrics of each target. We evaluate the system performance and the impact of different settings, including the distance between human and the device, user orientation, incidental angle, and blockage. Experimental results show that mmHRV can measure the HRV accurately with a median IBI estimation error of 28 ms (with respect to 96.16% accuracy). In addition, the root-mean-square error (RMSE) measured in the nonline-of-sight (NLOS) scenarios is 31.71 ms based on the experiments with 11 participants. The performance of the multiuser scenario is slightly degraded compared with the single-user case; however, the median error of the 3-user case is within 52 ms for all three tested locations.
AB - Heart rate variability (HRV), which measures the fluctuation of heartbeat intervals, has been considered as an important indicator for general health evaluation. To alleviate the user burden and explore the usability for long-term health monitoring, noncontact methods for HRV monitoring have drawn tremendous attention. In this article, we present mmHRV, the first contact-free multiuser HRV monitoring system using commercial millimeter-wave (mmWave) radio. The design of mmHRV consists of two key components. First, we develop a calibration-free target detector to identify each user's location. Second, a heartbeat signal extractor is devised, which can optimize the decomposition of the phase of the channel information modulated by the chest movement and, thus, estimate the heartbeat signal. The exact time of heartbeats is estimated by finding the peak location of the heartbeat signal while the interbeat intervals (IBIs) can be further derived for evaluating the HRV metrics of each target. We evaluate the system performance and the impact of different settings, including the distance between human and the device, user orientation, incidental angle, and blockage. Experimental results show that mmHRV can measure the HRV accurately with a median IBI estimation error of 28 ms (with respect to 96.16% accuracy). In addition, the root-mean-square error (RMSE) measured in the nonline-of-sight (NLOS) scenarios is 31.71 ms based on the experiments with 11 participants. The performance of the multiuser scenario is slightly degraded compared with the single-user case; however, the median error of the 3-user case is within 52 ms for all three tested locations.
KW - Heart rate variability (HRV)
KW - heartbeat estimation
KW - millimeter-wave (mmWave) radio
KW - wireless sensing
UR - http://www.scopus.com/inward/record.url?scp=85104581104&partnerID=8YFLogxK
U2 - 10.1109/JIOT.2021.3075167
DO - 10.1109/JIOT.2021.3075167
M3 - Article
AN - SCOPUS:85104581104
SN - 2327-4662
VL - 8
SP - 16623
EP - 16636
JO - IEEE Internet of Things Journal
JF - IEEE Internet of Things Journal
IS - 22
ER -