摘要
Methane/coal dust/air explosions under strong ignition conditions have been studied in a 199 mm inner diameter and 30.8 m long horizontal tube. A fuel gas/air manifold assembly was used to introduce methane and air into the experimental tube, and an array of 44 equally spaced dust dispersion units was used to disperse coal dust particles into the tube. The methane/coal dust/air mixture was ignited by a 7 m long epoxypropane mist cloud explosion. A deflagration-to-detonation transition (DDT) was observed, and a self-sustained detonation wave characterized by the existence of a transverse wave was propagated in the methane/coal dust/air mixtures.The suppressing effects on methane/coal dust/air mixture explosions of three solid particle suppressing agents have been studied. Coal dust and the suppressing agent were injected into the experimental tube by the dust dispersion units. The length of the suppression was 14 m. The suppression agents examined in this study comprised ABC powder, SiO2 powder, and rock dust powder (CaCO3). Methane/coal dust/air explosions can be efficiently suppressed by the suppression agents characterized by the rapid decrease in overpressure and propagating velocity of the explosion waves.
源语言 | 英语 |
---|---|
页(从-至) | 310-316 |
页数 | 7 |
期刊 | Journal of Loss Prevention in the Process Industries |
卷 | 26 |
期 | 2 |
DOI | |
出版状态 | 已出版 - 3月 2013 |